    生产运营过程中难免会遇到燃气发电机意外停机现象,对故障问题的精准判断直接关系到生产经营活动的恢复快慢,等等一些问题会出现,那么需要怎么防治呢?
    During the production and operation process, it is inevitable to encounter unexpected shutdown of gas generator. The accurate judgment of fault problems is directly related to the recovery speed of production and operation activities. Some problems will occur, so how to prevent them?
    加强日常巡检
    Strengthen daily inspection
    每日定点巡检,检查机组的各项参数,上位机系统可设置报警值。检查燃气发电机的转速、频率、出口电压、功率、机油压力、冷却水温度以及蓄电池电压等参数。
    Daily fixed-point patrol inspection, focusing on the inspection of various parameters of the unit, and the upper computer system can set the alarm value. The speed, frequency, outlet voltage, power, oil pressure, cooling water temperature, battery voltage and other parameters of the gas generator shall be mainly checked.
    现场查看燃气发电机冷却风扇的运转情况,冷却水管路和机油管路的渗漏情况,同时查看机油液位和冷却水液位。现场辨听燃气发电机运行时有无异常声响。手持测温枪对冷却风扇电机壳和气缸进行温度检测。
    Check the operation of the cooling fan of the gas generator, the leakage of the cooling water pipe and oil pipe, and check the oil level and cooling water level at the same time. Identify whether there is abnormal sound when the gas generator is running on site. Hold a temperature measuring gun to detect the temperature of the cooling fan motor housing and cylinder.
    维护保养
    Maintenance
    参考厂商提供的燃气发电机维保手册,结合现场实际运营经验,制定并严格执行合规的维保规程。维保级别一般有首保,500h维保,1000h维保,2000h维保,4000h维保,8000h维保以及中修和大修维保。
    Refer to the gas generator maintenance manual provided by the manufacturer and in combination with the actual operation experience on site, formulate and strictly implement the compliant maintenance procedures. Maintenance levels generally include first maintenance, 500h maintenance, 1000h maintenance, 2000h maintenance, 4000H maintenance, 8000h maintenance, and medium and overhaul maintenance.
    燃气榴莲视频在线观看污
    不同的维保级别对应不同的项目检查和部件更换。维保要做到全面,检查气门间隙,气门凸出量调整,曲轴箱呼吸器清洁,火花塞检查,正时传感器清洁,延时继电器和其他电气元件的检查,水路和油路的检查等。同时,控制系统接线松紧度以及各传感器探头的检查校准。
    Different maintenance levels correspond to different item inspections and component replacement. The maintenance shall be comprehensive, focusing on valve clearance, valve projection adjustment, crankcase breather cleaning, spark plug inspection, timing sensor cleaning, time delay relay and other electrical components inspection, water and oil circuit inspection, etc. At the same time, the tightness of the wiring of the control system and the inspection and calibration of each sensor probe.
    意外事件记录分析
    Accident record analysis
    燃气榴莲视频在线观看污运行过程中,注重常见故障和其他故障的分类总结、归类,制定一套事件应急处置卡,针对不同的故障类型编制不同的操作要求及部件更换。经过长期的意外停机事件积累,对于燃气发电机的故障处理能力会有明显的提升。
    During the operation of gas-fired generator units, attention shall be paid to the classification, summary and classification of common faults and other faults, a set of emergency response cards shall be developed, and different operation requirements and component replacement shall be prepared for different fault types. After the accumulation of long-term unexpected shutdown events, the fault handling capacity of gas generator will be significantly improved.
    加强人员培训考核加强站场相关人员对燃气发电机的掌握,逐步提高意外停机事件的应急响应机制和处理能力。通过岗位练兵和培训考核,保证人员对燃气发电机的熟悉掌握。同时,可以定期举办人员交流,分享彼此燃气发电机运维经验。
    Strengthen personnel training and assessment, strengthen the mastery of gas generator by relevant personnel in the station, and gradually improve the emergency response mechanism and handling capacity of unexpected shutdown events. Through on-the-job training and training assessment, ensure that professionals are familiar with gas generators. At the same time, regular personnel exchanges can be held to share each other's experience in gas generator operation and maintenance.
    以上便是问题的相关解答内容了,如果您想获取更多相关信息,就来关注榴莲视频IOS污网站http://www.wqeshop.com吧!
    The above is the relevant answers to the questions. If you want to get more relevant information, please follow our website http://www.wqeshop.com Come on!
    榴莲APP旧版本下载进入官网搜索
    济南济柴榴莲视频IOS污燃气发电设备有限公司
    • 服务热线

      0531-62325028
      0531-69951266

    针对燃气榴莲视频在线观看污问题的防范措施

    生产运营过程中难免会遇到燃气发电机意外停机现象,对故障问题的精准判断直接关系到生产经营活动的恢复快慢,等等一些问题会出现,那么需要怎么防治呢?
    During the production and operation process, it is inevitable to encounter unexpected shutdown of gas generator. The accurate judgment of fault problems is directly related to the recovery speed of production and operation activities. Some problems will occur, so how to prevent them?
    加强日常巡检
    Strengthen daily inspection
    每日定点巡检,检查机组的各项参数,上位机系统可设置报警值。检查燃气发电机的转速、频率、出口电压、功率、机油压力、冷却水温度以及蓄电池电压等参数。
    Daily fixed-point patrol inspection, focusing on the inspection of various parameters of the unit, and the upper computer system can set the alarm value. The speed, frequency, outlet voltage, power, oil pressure, cooling water temperature, battery voltage and other parameters of the gas generator shall be mainly checked.
    现场查看燃气发电机冷却风扇的运转情况,冷却水管路和机油管路的渗漏情况,同时查看机油液位和冷却水液位。现场辨听燃气发电机运行时有无异常声响。手持测温枪对冷却风扇电机壳和气缸进行温度检测。
    Check the operation of the cooling fan of the gas generator, the leakage of the cooling water pipe and oil pipe, and check the oil level and cooling water level at the same time. Identify whether there is abnormal sound when the gas generator is running on site. Hold a temperature measuring gun to detect the temperature of the cooling fan motor housing and cylinder.
    维护保养
    Maintenance
    参考厂商提供的燃气发电机维保手册,结合现场实际运营经验,制定并严格执行合规的维保规程。维保级别一般有首保,500h维保,1000h维保,2000h维保,4000h维保,8000h维保以及中修和大修维保。
    Refer to the gas generator maintenance manual provided by the manufacturer and in combination with the actual operation experience on site, formulate and strictly implement the compliant maintenance procedures. Maintenance levels generally include first maintenance, 500h maintenance, 1000h maintenance, 2000h maintenance, 4000H maintenance, 8000h maintenance, and medium and overhaul maintenance.
    燃气榴莲视频在线观看污
    不同的维保级别对应不同的项目检查和部件更换。维保要做到全面,检查气门间隙,气门凸出量调整,曲轴箱呼吸器清洁,火花塞检查,正时传感器清洁,延时继电器和其他电气元件的检查,水路和油路的检查等。同时,控制系统接线松紧度以及各传感器探头的检查校准。
    Different maintenance levels correspond to different item inspections and component replacement. The maintenance shall be comprehensive, focusing on valve clearance, valve projection adjustment, crankcase breather cleaning, spark plug inspection, timing sensor cleaning, time delay relay and other electrical components inspection, water and oil circuit inspection, etc. At the same time, the tightness of the wiring of the control system and the inspection and calibration of each sensor probe.
    意外事件记录分析
    Accident record analysis
    燃气榴莲视频在线观看污运行过程中,注重常见故障和其他故障的分类总结、归类,制定一套事件应急处置卡,针对不同的故障类型编制不同的操作要求及部件更换。经过长期的意外停机事件积累,对于燃气发电机的故障处理能力会有明显的提升。
    During the operation of gas-fired generator units, attention shall be paid to the classification, summary and classification of common faults and other faults, a set of emergency response cards shall be developed, and different operation requirements and component replacement shall be prepared for different fault types. After the accumulation of long-term unexpected shutdown events, the fault handling capacity of gas generator will be significantly improved.
    加强人员培训考核加强站场相关人员对燃气发电机的掌握,逐步提高意外停机事件的应急响应机制和处理能力。通过岗位练兵和培训考核,保证人员对燃气发电机的熟悉掌握。同时,可以定期举办人员交流,分享彼此燃气发电机运维经验。
    Strengthen personnel training and assessment, strengthen the mastery of gas generator by relevant personnel in the station, and gradually improve the emergency response mechanism and handling capacity of unexpected shutdown events. Through on-the-job training and training assessment, ensure that professionals are familiar with gas generators. At the same time, regular personnel exchanges can be held to share each other's experience in gas generator operation and maintenance.
    以上便是问题的相关解答内容了,如果您想获取更多相关信息,就来关注榴莲视频IOS污网站http://www.wqeshop.com吧!
    The above is the relevant answers to the questions. If you want to get more relevant information, please follow our website http://www.wqeshop.com Come on!